• Fixed Ultrasonic Flow Module U-100m

Fixed Ultrasonic Flow Module U-100m

Accuracy: ±0.6-1%
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil
Size: DN10-DN6000
Sensor: Clamp-on/External
Application: Industrial Production
Type: Ultrasonic Flow Meter
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
U-100M
Measuring Media
Liquid
Measuring Principle
Ultrasonic
Measurement Object
Closed Pipeline
Certification
DIN, GB, ISO
Name
Fixed Ultrasonic Flow Module U-100m
Indicator
Module
Sensor Type
Clamp on
Transport Package
Carton
Specification
ISO
Trademark
Beifang
Origin
China
HS Code
9026100000
Production Capacity
100 Sets/Month

Product Description

Fixed Ultrasonic Flow Module U-100M

Model: UFM/TDS-100M/U-100M


1. Accuracy: Better than 1%
2. Repeatability: 0.2%
3. Certifiacte: EMC and LVD Compliance certificat

Ultrasonic flowmeter including follow types:
Fixed, Portable, Handheld type,
Flange, Insertion, Clamp-on sensor type,
Battery powered, Heat flow type ect.


 
                                   The  specifications of our Fixed ultrasonic flow meter
Measuring Principle Ultrasonic wave transmission time difference principle, dual CPU working in parallel, 4-byte floating-point operations
Accuracy Better than ± 1.0 %
Repeatability 0.2%
Velocity 0.03-± 32 m/s
Measurement Period 0.5S
Display Backlit LCD can display 2x20 letters instantaneous flow, cumulative flow, velocity, time, calories and other data signal output at the same time etc.
Keypad 4x4-key membrane keypad with tactile feedback
Input Can input two current signals(such as: temperature, pressure, liquid level, etc. signals ) in order to achieve heat measurements or a dual-purpose machine
Output Electric current signal    4-20mA or 0-20mA, etc. RS 485 Impedance 0 - 1K, accuracy 0.1%
Isolated OCT output For frequency output (0-9, 999Hz)
Internal Alarm (Buzzer) User programmable
External Alarm Driver Alarm signal can be transmitted to Relay or OCT
output terminals to drive an externa alarm.  
Data Interface RS-232 serial port.
Power AC: 220V    DC: 8~36VDC or AC7-30V
Power Consumption < 2W
Work time Continuous
Environment Temperature -30-80 Degrees Celsius
Environment Humidity 85% RH

 

 

Product Features:
Product      Features 1. Bi-directional measurement, can measure the positive and negative, the net cumulative flow
2. Automatic memory before 64 days prior 64 months, the first 5 years of light product flow rate
3. Automatic memory 64 days before the working status of flow met er
4. Auto memory the former 64 times more time and power flows can be manual or automatic inspection in order to reduce the flow losses
5. Programmable volume (quantitative) Controller
6. Configure GPRS / GSM module enables remote monitoring and control


Fixed Ultrasonic Flow Module U-100m



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now