Customization: | Available |
---|---|
Accuracy: | ±0.6-1% |
Main Application: | Water, Wastewater, Diesel Fuel, Fuel Oil |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item | Krohne Variable area flowmeter |
Metering range(100% values) | Water(20° C) 6~15000 l/h Air (0.1013MPa 20° C) 0.05~4000 m 3 /h |
Rangeability | 10: 1 |
Accuracy class | 1.5 (Special version 1.0) |
Operating data | |
Max pressure | DN15~DN50 PN4.0MPa (Special versio 25MPa) DN80~DN100 PN1.6MPa (Special versio 16MPa) |
Temperature of fluid | -80° C~+220° C |
Ambient temperature | Max 120° C(Max. 60° C if signal output is electrical) |
Current output | 4-20mA (Optional) |
Viscosity of fluid | DN15: ≤ 5mPa. s(H15.1~H15.3) ≤ 30mPa. s(H15.4~H15.9) DN25: ≤ 250mPa. s DN50~DN150: ≤ 300mPa. s |
Connection Standard | Flange to DIN2501 or ANSI , Special Other standards on request |
Electaic | M20× 1.5, PG11, 1/2" NPT |
Owerall height | 250mm |
Protection category to DIN 40050 | IP65 |
Explosion Proof | ExiaIICT3~6 ExdIIBT4 |