• Krohne Float Flow Meter (DK32)
  • Krohne Float Flow Meter (DK32)
  • Krohne Float Flow Meter (DK32)
  • Krohne Float Flow Meter (DK32)

Krohne Float Flow Meter (DK32)

Accuracy: ±0.6-1%
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas
Sensor: Tube/Flange
Type: Variable Area Flow Meter
Measuring Media: Liquid
Measuring Principle: Mechanics
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
DK32
Certification
DIN, GB, CE, ISO
Temperature of Fluid
-80c~90c
Protection
IP65
Connection
Horizental
Transport Package
Package
Specification
Krohne
Trademark
Krohne
Origin
Germany
Production Capacity
100 Sets/Month

Product Description

Krohne Variable area flow meter DK32/DK34

Range: DN15---DN300
Measure Liquid, gas, vapor
Connection: Horizontal or Vertical
Temperature: -80C---300C
Model DK32 has same connection, special in measure slight flow

Metal tube rotameter
Special features:
1. Rugged all-metal design
2. Easy stocking of parts thanks to modular concept
3. Complete interchangeability of all components and assemblies
4. Linear display
5. Adjustable to any fluid through replaceable cam plate
6. Shot-stroke design/parts do not project beyond the flanges, no matter what position the float is in
7. Electrical or pneumatic remote data transmission system
8. Limit switches can be installed
  Item   Krohne Variable area flow meter
  Metering range(100% values)   Water(20° C)                                        6~15000 l/h
  Air  (0.1013MPa 20° C)              0.05~4000 m 3 /h
  Rangeability   10: 1
  Accuracy class    1.5 (Special version 1.0)
  Operating data
 
  Max pressure   DN15~DN50      PN4.0MPa (Special versio 25MPa)
  DN80~DN100  PN1.6MPa (Special versio 16MPa)
  Temperature of fluid   -80° C~+220° C
  Ambient temperature   Max 120° C(Max. 60° C if signal output is electrical)
  Current output   4-20mA (Optional)
  Viscosity of fluid   DN15: ≤ 5mPa. s(H15.1~H15.3)
                    ≤ 30mPa. s(H15.4~H15.9)
  DN25: ≤ 250mPa. s       
  DN50~DN150: ≤ 300mPa. s
  Connection Standard   Flange to DIN2501 or ANSI  , Special  Other standards on request
  Electaic    M20× 1.5, PG11, 1/2" NPT
  Owerall height   250mm
  Protection category to DIN 40050   IP65
  Explosion Proof   ExiaIICT3~6
  ExdIIBT4




Krohne Float Flow Meter (DK32)
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now