Clamp Hoop Magnetic Flow Meter

Product Details
Customization: Available
Accuracy: ±0.2-0.5%
Main Application: Water, Wastewater, Corrosive Liquid/Gas
Gold Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
86
Management System Certification
ISO 9001, ISO 9000, QC 080000, ISO 22000,ISO 29001
  • Clamp Hoop Magnetic Flow Meter
  • Clamp Hoop Magnetic Flow Meter
Find Similar Products

Basic Info.

Model NO.
EFM
Size
DN10-DN1200
Sensor
Tube/Flange
Type
Electromagnetic Flow Meter
Measuring Media
Liquid
Measuring Principle
Electrical Principles
Certification
DIN, GB, CE, ISO
Measure Range
DN15~DN6000
Temperature
-30c~160 Degre C
Connetion
Flange, Thread, Plug-in
Transport Package
Wooden
Trademark
Beifang
Origin
China
Production Capacity
100 Sets/Month

Product Description

Clamp Hoop Magnetic flow meter

1. Electromagnetic flowmeter
2. Accuracy: 0.5%
3. Size: DN15-DN3000
4. Protection grad: IP67 or IP68
5. 4-20mA, RS485/RS232, Hart, Pulse
6. Integrate, Remote type is optional
                                      The Specifications of  Electromagnetic flowmeter
Measuring fluid Conductive fluid
Accuracy 0.2%, 0.3%
Repeatability 0.06%, 0.1%
Temperature range of fluid -25---180 C
Rated pressure DN25--DN150: 4.0Mpa    , DN200--DN1000: 1.0Mpa      , DN1100--DN2000: 0.6Mpa,     DN2200--DN3200: 0.25Mpa
Flowrate range of media 0.3---12m/s
Conductivity   ≥ 1μ   s/cm, ≥ 5μ   s/cm
Electrode material 316SS, Hastelloy alloy B, Hastelloy alloy C, titanium, platinum dissolution, tungsten carbide, etc.
Number of electrode 2electrodes(standard), 4 eletrodes (≤ DN500), 6 eletrodes(≤ DN600)
Lining materials Chloroprene rubber, PTFE F4, FEP copolymer F46, polyurethane rubber and so on
Flange material of bulk 304SS, 20# carbon steel and other materials (special orders)
Installation forms Holder-style (≤ DN300), flange connected (≤ DN350)
Protection grade IP67, IP68
Power supply of converter 220V± 20%, 60 HZ/ 24VDC (opional frome the two)
Signal output Standard: Pulse, and 4--20mA, RS485, Hart protocol and MODERBUS protocol are optional.
Structural form Integrative type  and splite type(with 5m standard cables)
Power consumption 0.65W
Working environment Environmental temperature: -25~60oC,
Humidity: 0.5%--90%
Disply interface of converter LCD and operation interfaces entirely in English that are able to display instantaneous flow, cumulative flow, and multiple flow units can be selected.