Customization: | Available |
---|---|
Accuracy: | 0.2% |
Main Application: | Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item Target flowmeter Performance, Parameters | |
Medium | Liquid, Gas and Steam |
Caliber | Pipe type 15~300mm Clamp type 15~600mm Plug type100~2000mm |
Pressure | 0.6~10MPa 0.6~42MPa 0.6~42MPa |
Accuracy | ± 0.2 ~ ± 1.5%FS |
Medium Temperature | -196° C~+450° C ( Confirming the temperature range before purchase) |
Media temperature | -20 ~ +70 (normal temperature type) -196 ~ +700 (high/low temperature type) |
Precision | ± 0.2% ± 0.5% ± 1.0% ± 1.5% ± 2.5% |
Range | 1: 3 1: 5 1: 10 1: 10 1: 10(Steam) |
Compensation | Temperature compensation; Pressure compensation |
Repeatability | 0.1%~0.08% |
Power Supply | 3.6V lithium battery, 24V DC |
Output | LCD display, and 4~20mA, 0~10V, impulse or RS485 (Optional) |
Material of measure tube | Carbon Steel; 304; 316L; Being able to provide other according to user requests |
Explosion- Prevent Symbol | ExiallCT4, ExiallBT4 |
Protection Rank | IP65; IP67 |
Features |
* Installation is simple and convenient, easy to maintain * A variety of output forms, spread far and wide variety of parameters * Anti-vibration is strong, within a certain range can be measured pulsatile flow * Anti-jamming, anti-contamination ability to exceptionally strong |