Variable Area Flowmeter Dk32/Dk34

Product Details
Customization: Available
Accuracy: ±0.6-1%
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas
Gold Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
86
Management System Certification
ISO 9001, ISO 9000, QC 080000, ISO 22000,ISO 29001
Find Similar Products

Basic Info.

Model NO.
DK34
Sensor
Tube/Flange
Application
Industrial Production
Type
Variable Area Flow Meter
Measuring Media
Liquid
Measuring Principle
Mechanics
Measurement Object
Closed Pipeline
Certification
DIN, ANS, GB, CE, ISO
Range
Dn15~Dn300
Medium
Liquid, Gas, Vapor
Transport Package
Carton
Specification
Krohne
Trademark
Krohne
Origin
Germany
HS Code
902610000
Production Capacity
300 Sets/Month

Product Description

Krohne Variable area flowmeter DK34

Range: DN15---DN300
Measure Liquid, gas, vapor
Connection: Horizontal or Vertical
Temperature: -80C---300C
Model DK32 has same connection, special in measure slight flow

Metal tube rotameter
Special features:
1. Rugged all-metal design
2. Easy stocking of parts thanks to modular concept
3. Complete interchangeability of all components and assemblies
4. Linear display
5. Adjustable to any fluid through replaceable cam plate
6. Shot-stroke design/parts do not project beyond the flanges, no matter what position the float is in
7. Electrical or pneumatic remote data transmission system
8. Limit switches can be installed
  Item   Krohne Variable area flowmeter
  Metering range(100% values)   Water(20° C)                             6~15000 l/h
  Air  (0.1013MPa 20° C)              0.05~4000 m 3 /h
  Rangeability   10: 1
  Accuracy class    1.5 (Special version 1.0)
  Operating data
 
  Max pressure   DN15~DN50      PN4.0MPa (Special versio 25MPa)
  DN80~DN100  PN1.6MPa (Special versio 16MPa)
  Temperature of fluid   -80° C~+220° C
  Ambient temperature   Max 120° C(Max. 60° C if signal output is electrical)
  Current output   4-20mA (Optional)
  Viscosity of fluid   DN15: ≤ 5mPa. s(H15.1~H15.3)
               ≤ 30mPa. s(H15.4~H15.9)
  DN25: ≤ 250mPa. s       
  DN50~DN150: ≤ 300mPa. s
  Connection Standard   Flange to DIN2501 or ANSI  , Special  Other standards on request
  Electaic    M20× 1.5, PG11, 1/2" NPT
  Owerall height   250mm
  Protection category to DIN 40050   IP65
  Explosion Proof   ExiaIICT3~6
  ExdIIBT4



Variable Area Flowmeter Dk32/Dk34
 